Part number definition GY——Communication room (field) outdoor optical cable T ——filled structure A ——Aluminum-polyethylene bonded sheath GYTA (metal strengthening member, loose tube stranded and filled, aluminum-polyethylene bonded sheathed outdoor optical fiber cable for communication) The structure of the optical cable is to sheath single-mode or multi-mode optical fiber into the inner filling made of high modulus plastic Waterproof compound in loose tube. The center of the cable core is a metal reinforced core. For some fiber optic cables, the metal reinforced core is also extruded with a layer of polyethylene (PE). The loose tube (and filling rope) is twisted around the central reinforcing core to form a compact and circular cable core, and the gaps in the cable core are filled with water blocking compounds. The aluminum-plastic composite tape is longitudinally wrapped and then extruded with a polyethylene sheath. ●Precise control of the excess length of the optical fiber ensures that the optical cable has good tensile performance and temperature characteristics ●PBT loose tube material has good hydrolysis resistance, and the tube is filled with special grease to protect the optical fiber ●PE sheath has good resistance to solar radiation ●Smooth outer sheath enables the optical cable to have a smaller coefficient of friction during installation ●The following measures are taken to ensure the waterproof performance of the optical cable: special waterproof compound is filled in the loose tube; completely filled with the cable core; aluminum-plastic composite with moisture-proof layer ●The side pressure index of aluminum belt is not as good as that of steel belt, but the moisture-proof and rust-proof effect is better than that of steel belt. GYTA has a long life when used in pipes. Applicable laying ● Aerial laying Structure Technical parameter Cable Type(Increased by 2 bers) Fiber Count Tubes Fillers Cable Diameter (mm) Cable Weight (kg/km) Tensile Strength: Long/Short term (N) Crush Resistance: Long/Short term (N/100mm) Bending Radius Static/Dynamic (mm) 2~6 1 4 9.2 80 600/1500 300/1000 10D/20D 8~12 2 3 9.2 80 600/1500 300/1000 10D/20D 3 2 9.2 80 600/1500 300/1000 10D/20D 4 1 9.2 80 600/1500 300/1000 10D/20D 5 0 9.2 80 600/1500 300/1000 10D/20D 6 0 9.7 97 1000/3000 300/1000 10D/20D 4 1 10.5 109 1000/3000 300/1000 10D/20D 5 0 10.5 109 1000/3000 300/1000 10D/20D 6 0 11.5 126 1000/3000 300/1000 10D/20D 7 1 13.2 153 1000/3000 300/1000 10D/20D 8 0 13.2 153 1000/3000 300/1000 10D/20D 98-108 9 1 14.6 182 1000/3000 300/1000 10D/20D 10 0 14.6 182 1000/3000 300/1000 10D/20D 1 16.5 221 1000/3000 300/1000 10D/20D 12 0 16.5 221 1000/3000 300/1000 10D/20D 16.5 222 1000/3000 300/1000 10D/20DGY Communication room (field) outdoor optical cable none no reinforcement B Flat shape A Aluminum-polyethylene bonded sheath 5 Corrugated steel belt Codename Coating or jacket code A1a IEC and GB/T G.651 GH Submarine Optical Cable for Communication F Non-metallic reinforcement C Self-supporting structure G Steel sheath 44 Double thick round steel wire 1 Fiber cover A1b IEC and GB/T G.651 GJ Optical cable in communication room (office) G Metal heavy reinforcement D Fiber ribbon structure L Aluminum sheath 4 Single thick round steel wire 2 Polyethylene protection tube A1c IEC and GB/T G.651 GR Flexible Optical Cable for Communication H Non-metallic heavy-duty reinforcement E Oval shape Q Lead sheath 33 Double thin round steel wire 3 Polyethylene sleeve A1d IEC and GB/T G.651 GS Optical fiber cable in communication equipment G Skeleton trough structure S Steel-polyethylene bonded magnetic protection 3 Single thin round steel wire 4 Polyethylene sleeve and nylon sleeve B1.1 (B1) Non-dispersion shifted fiber G652 GT Special optical cable for communication J Fiber tight sleeve coating structure U Polyurethane sheath 2 Double steel belt 5 PVC sleeve B1.2 Cut-off wavelength shifted fiber G654 GW Metal-free optical cable for communication R Inflatable structure V PVC sheath 0 No armor layer B1.3 IEC and GB/T G.652C GM Mobile optical cable for communication T Grease filled structure W Steel-polyethylene bonded sheath with parallel steel wires B2 Dispersion shift type optical cable G653 X Cable bundle tube (coating) structure Y Polyethylene sheath B4 Non-zero dispersion shifted fiber G655 Z Flame retardant Product description
Features
● Wear tube/blowing in tube
G.652 G.655 50/125 pm 62.5/125 pm Attenuation(+20 C) @ 850 nm < 3.0 dB/km < 3.3 dB/km @ 1300 nm < 1.0 dB/km < 1.0 dB/km @1310 nm < 0.36 dB/km < 0.40 dB/km @ 1550 nm < 0.22 dB/km < 0.23 dB/km Bandwidth(Class A) @ 850 nm > 500 MHz-km > 200 MHz-km @ 1300 nm > 1000 MHz-km > 600 MHz-km Numerical Aperture 0.200±0.015NA 0.275±0.015NA Cable Cut-off Wavelength 入cc < 1260 nm < 1450 nm GYTA-2-6 GYTA-8-12 GYTA-14-18 14-18 GYTA-20-24 20-24 GYTA-26-30 26 〜30 GYTA-32-36 32 〜36 GYTA-38-48 38-48 GYTA-50-60 50-60 GYTA-62-72 62-72 GYTA-74-84 74-84 GYTA-86-96 86-96 GYTA-98-108 GYTA-110-120 110-120 GYTA-122-132 122-132 11 GYTA-134 〜144 134-144 GYTA-146-288 146-288