XHHW building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). XHHW CU is permitted for 600-volt applications and can be used in wet locations at temperatures not to exceed 75ºC or dry locations at temperatures not to exceed90ºC. It's suitable for applications requiring low-leaking circuits and a dielectric c

XHHW building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). XHHW CU is permitted for 600-volt applications and can be used in wet locations at temperatures not to exceed 75ºC or dry locations at temperatures not to exceed90ºC. It's suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less. With the special insulation, the wire requires no lubrication for installation.


STANDARDS
 The following standards form a part of this specification to the extent specified herein:
1 Underwriters Laboratories Standard 44 for Rubber-Insulated Wires and Cables.
2 ICEA Pub. No. S-95-658, NEMA Pub. No. WC70 for Nonshielded Power Cables Rated 2000 Volts or Less.
3 Federal Specification J-C-30B.

 CONDUCTORS

Conductors shall be Class B stranded annealed uncoated copper /8000Series Aluminum Alloy per UL Standard 44.

 SEPARATOR

 A suitable separator over the conductor may be used at the option of the manufacturer.

 INSULATION

1 Each conductor shall be insulated with XLP, a crosslinked polyethylene complying with the physical and electrical requirements of UL Standard 44 for Type XHHW-2.
2 The average thickness of insulation, for a given conductor size, shall be as specified in UL Standard 44 for Type XHHW-2. The minimum thickness at any point shall be not less than 90% of the specified average thickness. The insulation shall be applied tightly to the conductor and shall be free-stripping.

 IDENTIFICATION

 The wire shall be identified by surface marking indicating manufacturer's identification, conductor size and metal, voltage rating, UL Symbol and type designation.

 TESTS

Wire shall be tested in accordance with the requirements of UL Standard 44 for Type XHHW-2.

 LABELS

The wire shall bear the Underwriters Laboratories label for Type XHHW-2.

SizeStrandingConductor DiameterInsulation ThicknessOverall DiameterWeightAmpacity at 90C *
AWG(inches)(inches)(inches)LBS/1000'A
870.1340.0450.2273045
670.1690.0450.2624260
470.2130.0450.3066875
270.2680.0450.36186100
170.2990.550.412110115
1/0180.3350.550.449134135
2/0180.3780.550.489163150
3/0180.4230.550.536200175
4/0180.4760.550.588247205
250350.520.650.653296230
300350.5710.650.703359255
350350.6140.650.749401280
400350.6570.650.792453305
500350.7360.650.869556350
600580.8160.80.979679385
700580.8770.81.04782420
750580.9090.81.071833435
900580.9990.81.162987480
1000581.0590.81.2231090500

 


XHHW Cable
XHHW building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). XHHW CU is permitted for 600-volt applications and can be used in wet locations at temperatures not to exceed 75ºC or dry locations at temperatures not to exceed90ºC. It's suitable for applications requiring low-leaking circuits and a dielectric c
Long press to look detail
Long by picture save/share
INQUIRY

ONLINE INQUIRY MORE+
  • Name *

  • E-mail *

  • Phone

  • Describe

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

XHHW Cable

Inquire Now
INQUIRY

ONLINE INQUIRY MORE+
  • Name *

  • E-mail *

  • Phone

  • Describe

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Contact Supplier

Send your message to this supplier

  • Name *

  • Email *

Subscribe

Security Code
Refresh the code
Cancel
Confirm

About Us

Products

About Us

Products

News

Copyright © Hualue Co., Ltd   All Rights Reserved. 

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.